  1. Steel Lintels should be installed with a minimum end bearing of 150mm, bedded on mortar and levelled along its length and across its width.
  2. The masonry above the lintel should be built in accordance with BS EN 1996-2:2006.
  3. Raise the inner and outer leaves simultaneously to avoid excessive eccentricity of loading, with a maximum height difference of 225mm (Masonry should be laid on a mortar bed and all perpendicular joints should be filled.)
  4. Allow the mortar to cure before applying floor or roof loads (Temporary propping beneath a steel lintel is practised to facilitate speed of construction).
  5. The NHBC recommend a damp proof course (DPC) or cavity tray should be installed over all openings in external cavity walls.
  6. When installing concrete floor units or other heavy components above a lintel, care should be taken to avoid shock loading and floor units should not be dragged into position. Masonry immediately above the lintel should be allowed to cure.
  7. Point loads should not be applied directly onto lintel flanges. Steel Lintels should have a minimum of masonry 150mm high between the flange and the application level of any form of loading. Consult IG's technical department if applying a point load above lintels.
  8. The external lintel flange must project beyond the window/door frame and it is recommended that a flexible sealing compound is used between the underside of the lintel flange and the frame.
  9. When the underside of a lintel is exposed, its appearance can be enhanced by the addition of lintel soffit cladding.
  10. Do not cut lintels to length or modify them in any way without consulting an IG engineer.

Allow the mortar to dry completely according to manufacturer's instructions, before moving ahead with a window or door installation. Have a helper assist you in the installation of steel lintel. Steel is a very heavy material, and lifting a lintel to a high position and securing it in place can be dangerous.

Lintel position within a cavity wall

Door
  1. Steel Lintels should be installed with a minimum end bearing of 150mm, bedded on mortar and levelled along its length and across its width.
  2. The masonry above the lintel should be built in accordance with BS EN 1996-2:2006.
  3. Raise the inner and outer leaves simultaneously to avoid excessive eccentricity of loading, with a maximum height difference of 225mm (Masonry should be laid on a mortar bed and all perpendicular joints should be filled.)
  4. Allow the mortar to cure before applying floor or roof loads (Temporary propping beneath a steel lintel is practised to facilitate speed of construction).
  5. The NHBC recommend a damp proof course (DPC) or cavity tray should be installed over all openings in external cavity walls.
  6. When installing concrete floor units or other heavy components above a lintel, care should be taken to avoid shock loading and floor units should not be dragged into position. Masonry immediately above the lintel should be allowed to cure.
  7. Point loads should not be applied directly onto lintel flanges. Steel Lintels should have a minimum of masonry 150mm high between the flange and the application level of any form of loading. Consult IG's technical department if applying a point load above lintels.
  8. The external lintel flange must project beyond the window/door frame and it is recommended that a flexible sealing compound is used between the underside of the lintel flange and the frame.
  9. When the underside of a lintel is exposed, its appearance can be enhanced by the addition of lintel soffit cladding.
  10. Do not cut lintels to length or modify them in any way without consulting an IG engineer.

Allow the mortar to dry completely according to manufacturer's instructions, before moving ahead with a window or door installation. Have a helper assist you in the installation of steel lintel. Steel is a very heavy material, and lifting a lintel to a high position and securing it in place can be dangerous.

Lintel position within a cavity wall

Lintels are lifted into position whilst constructing brickwork, which may be done manually or by assistance of a crane. Usually a small gap is left above a window or door frame, to ensure that the lintel is supporting the load, as well as allowing for minor movements such as settlement of foundations or swelling of the frame itself. Masonry above the lintel should be allowed to cure before applying floor or roof loads. Installation tips for concrete lintels. Recommended bearings are 100mm for openings of up to 1m, and 150mm for openings over 1m. Minimum recommended lintel depth is 140mm in order to absorb the shock loading of a concrete floor. Lintel Garage Door Installation. By hardesearchlebs1974 Follow Public. The finished opening should be the exact dimension of the door. Reduce two 2 x 6 parts of wood, and attach to the encounter of the wall operating from the advantage of your garage door jambs to the ceiling of your garage area. My client is selling their house and the buyer's inspector pointed out 'the overhead garage door lintel is sagging and there are brickwork cracks as a result'. In his opinion the lintel used when the house was constructed in 2008 was not heavy enough. They are asking for seller concessions as my client is not interested in making repairs.

In accordance with BS EN 1996-2:2006 and NHBC requirements all external wall lintels MUST be installed with a flexible damp proof course with the exception of those adequately protected by an eaves overhang or similar form of protection. Sony icd px720 driver windows 7.

  • Lintel should be centred in the cavity and the distance between lintel up-stand within the cavity and masonry must not exceed 10mm
  • Masonry should not overhang any flange by more than 25mm.

Propping

Garage Door Lintel Calculations

The practice of propping a lintel is sometimes used to facilitate speed of construction. It should only be introduced after initial masonry load has been applied to the lintel.
When propping a lintel, a horizontal timber plank should be placed along the underside of the lintel and suitable* props secured into place at maximum 1200mm centres.
* Suitability of props is the responsibility of site management. Torrent video copilot element 3d all 7 packs crack mac os 10.8.